When deciding upon the specifications of a residential hangar home one of the decisions we face is how high to make the ceilings and main doors of the hangar. Besides factors of cost, there are a few specific issues that should be addressed as one endeavors to make that decision. These factors have to do with the Building Codes themselves as well as the size of the equipment that we intend to park within the confines of the hangar.. As most of us have discovered in our lives, we tend to fill every available nook and cranny of our existence with our “stuff”. George Carlin had a great bit regarding the subject which is hilarious to hear as it hits very close to the truth in most of our lives. A hangar is no exception. Of course we keep our airplane(s) in the hangar but usually that space becomes home to much, much more. One key possession that more and more folks are storing in their hangers is their motor home RV’s . So a common question, when designing a hangar home, whether or not the owner owns a motor home or not (because he should consider future owners), is how large and how high do we build the hangar to accommodate not only our airplane(s) also our RV’s. Here are some factors to consider:

THE RULES (ie, the Codes)

When I speak of the rules I am talking about the Building Code. Speaking specifically of “residential aircraft hangars” there are height limitations which are voiced in the code which can become factors when determining the ceiling height of the structure. The building code does not address, directly, the height of the ceiling but it does address the overall building height as measured by the average height of its highest roof plane. This can certainly relate to ceiling heights. This factor becomes more complicated if one is looking to build a residential home above the hangar and this factor, occasionally, can affect the entire project.. As a side, future articles will address this interesting conundrum in the industry with specific recommendations as to how to handle. But for our purposes here, generally, ceiling height and the code limitations, as currently written, are such that most reasonable heights, within a one story structure, will comply with the Code.

AIRCRAFT TAIL HEIGHTS

Let’s face it, the main reason for a hangar home is to store our precious airplanes. Most general aviation aircraft have tail heights significantly less than 14 feet. Unless one is parking his or her Airbus or some type of airliner or large twin in the hangar, he or she can be quite certain that most airplanes will fit into hangers with clearances as low as 12 feet. Most Beechcraft airplanes will fit through a door opening with a 14 foot high clearance with the exceptions of all the King Air’s and Queen Air’s. Even the Beechcraft Baren and the twin Bonanzas will fit through a 12 foot high opening.. Most of the Cessna’s will fit with the exceptions of the Caravans and the Citations. Bottom line, if you are flying a jet or large twin of most any manufacturer then you will likely be wanting a hangar much larger than the 2000 ft.² limitation for residential hangar and you will want a door and ceiling height of appropriate heights. If you are operating in that range of aircraft you undoubtedly know the height of your aircraft and will give your designer appropriate instructions to accommodate the sizes. However, for most GA aircrafts, the 12 to 13 foot height is quite appropriate and will fit most anything that we see in the typical aviation communities.

MOTORHOME HEIGHTS

Motor homes come in a wide range of heights. When deciding on the specifications of a residential hangar home, one of the decisions is how high to make the ceilings and main doors of the hangar. This includes consideration of the height of motor homes that may be stored in the hangar. When designing and building a hangar home, it's essential to consider the size and height of the equipment that will be parked within the hangar. When the I designed and built my own hangar home, 18 years ago, I placed an actual motor home door in the front of the hangar. The door is 12 feet high, which I considered sufficiently appropriate for any motor home that I'd realistically obtain. However, since then, many motor homes are being built with heights that exceed 12 feet, although even the large ones do not necessarily exceed 12 feet. For example, the my son has a 36-foot motor home, which easily fits through the 12-foot high door with no issues, despite having a “basement” and other luxury features. However, the length is tight, and a typical 2000 sqft hangar (50’x40’ is a typical footprint) leaves only about 38’8” inside dimension to fit the unit. This may be workable but tight by many standards. The limitations on motor homes heights, by law at the time of this writing, is 13 feet and 6 inches. Extremely large motor homes such as the Provost style coaches (sizes 40’ or longer) can exceed 13 feet. However, even the largest of these, at the time of this writing, rarely reach 13 feet. If a Residential Aircraft Hangar is being contemplated (2000 sqft limit), then any motor home that would reasonably fit will be unlikely to exceed 12 feet in height. Frankly, I think that my  12-foot height is quite appropriate for a smaller hangar my size hangar. About 2 years ago my wife and I did purchase a 28 foot Class C motorhome (a perfect size for us). We store it in the hangar, of course, and park a Smart Car behind and parallel to it. Plenty of room. However, a good rule of thumb for residential hangars is that a 13-foot height is more than sufficient for anything that one might reasonably be storing. As with airplanes, the larger hangars may require greater heights of ceiling and doors. However 14 feet would be a comfortable height for hangars all the way up to 4000 ft.². Above that, owners may be considering much larger airplanes, and the airplane, not the motor home, will become the basis for the design of all height clearances.

HEADERS ABOVE HANGAR DOORS

Obviously, ceiling height and hangar door opening heights might be different. If the structural span over the hangar door is designed correctly, one can eliminate the need for a header extending down below the ceiling and can actually make the door height and ceiling heights very close together indeed. However, this is dependent upon the type of hangar door chosen, and these factors must be considered during the design process.

SUMMARY

When building a Residential Aircraft Hangar of typical size of 50 feet wide by 40 feet deep, a good target for height is for the ceilings to be placed at 13’4” above the hangar floor (this is a perfect height for masonry walls and can be easily achieved regardless of the material used), and to make the door 13 feet high. Larger hangars should have ceiling and door heights of at least 14 feet. This will accommodate most any aircraft that can reasonably be fit within the space, as well as most motor homes. Of course, there are always exceptions, but this should serve as a good rule of thumb. As always, you can contact me any time with questions.

Timberhouse Aero Estates

by Engineer Designer on February 26, 2014

In Lafayette, Indiana, home of Purdue University, is nestled the flying community called Timberhouse Aero Estates. This small and peaceful community, consisting of 23 estate size lots, is perfect for any who love aviation, horses and outdoor activities. The property is less than an hour away from the Indianapolis Speedway and less than two hours away from Chicago. timberhouseaero (4) Lot sizes vary between 2 and 11 acres each. And even though this community is near the conveniences of medium and large cities, it still is a country setting for folks who want to horseback ride or even participate cross-country skiing. The community consists of 125 total acres carved out of the surrounding 400 acre farm called Timberhouse. It is relatively new with most of the 23 lots available for sale as of early 2014. timberhouseaero (3) The runway is a 3000 foot long grass runway. Personally, I love grass runways especially if they are maintained well. This particular runway appears to have been well designed with drain tiles having been run the full length of the runway which carry moisture away from the runway surface. If you want to fly in there to check it out, the Unicom frequency is 122.75. The runway is lit. timberhouseaero (2) The covenants are relatively simple with strategic rules to maintain the aesthetically pleasing nature of the community. Home sizes must be at least 2000 ft.² and hangar sizes must be at least 1600 ft.². If you are building there, it is not required that you build the hangar but you must place the home on the property in such a way that a hangar can be eventually built either by yourself or a future owner. timberhouseaero (1) This appears to be a charming community located in the Midwest near enough to key educational and business areas to suit either those still active in the work world or those desiring to retire to a country setting. Click here for more information.  

Torchport Airpark

by Engineer Designer on February 26, 2014

Located in North West Michigan, Torchport Airpark is a northern climate community located in one of the most beautiful regions of Michigan. It is tucked between Torch Lake and Lake Michigan and surrounded by hundreds of acres of beautiful forests. touchport (3) It is near Charlevoix and Traverse City on US 31. It is near clean lakes, at least four golf courses, excellent health facilities, sandy beaches of Lake Michigan, boat launch sites for those who love to float as much they do aviation, and, of course, near many areas rich in northern sports such as cross country skiing, snowboarding in overland hiking with snowshoes. touchport (2) The ownership has been set up in such a way that if you live and own a site in the area you will never lose the right to use and manage the runway. This is an important feature to consider with any airpark in that some are using a barrowed runway with rights that can be gone with the wind. Not so at Touchport. touchport (1) Typical homesites run 1 acre. Homes can be either attached or detached from the hangar. Homes must have a minimum of at least 1400 ft.² on the main floor, exclusive of decks, porches, garages and hangars. Garages must be built and have a minimum of 576 ft.². Buildings which are built as separate structures must conform with each other in terms of quality and materials. Such restrictions are important to maintain a minimum standard of quality and folks never regret living in the community with standards such as these. All utilities are underground. Wells and septic tanks need to be placed on each site for each project. There are two runways, one 9/27 and the other 4/22. 9/27 is 3300 feet long by 100 feet wide and 4/22 is 2600 feet long by 100 feet wide. The CTAF is 122.9. touchport (4) If you love the north, there is no better place than northern Michigan. Click here to learn more.